MC top-level constant
String
const MC
Media Copy.
Representation: CSI s \x69
Parameter default value: s = 0
MC is used either to initiate a transfer of data from or to an auxiliary input/output device or to enable or disable the relay of the received data stream to an auxiliary input/output device, depending on the parameter value:
- 0 - initiate transfer to a primary auxiliary device
- 1 - initiate transfer from a primary auxiliary device
- 2 - initiate transfer to a secondary auxiliary device
- 3 - initiate transfer from a secondary auxiliary device
- 4 - stop relay to a primary auxiliary device
- 5 - start relay to a primary auxiliary device
- 6 - stop relay to a secondary auxiliary device
- 7 - start relay to a secondary auxiliary device
This control function may not be used to switch on or off an auxiliary device.
Implementation
const String MC = 'i';